MN-35947 REV. 2 01/14
CTP6-10E, CTP6-10G
CTP10-10E, CTP10-10G
CTP7-20E, CTP7-20G
CTP10-20E, CTP10-20G
CTP20-10E, CTP20-10G
CTP20-20E, CTP20-20G

PHONE

U.S.A./CANADA
FAX

U.S.A. ONLY

d u e t o o n g o i n g p r o du c t i m p r o V e m e n t , s p e c i f i ca t i o n s a r e s u b J e c t t o c h a n g e W i t h o u t n o t ic e .p r i n t e d i n u . s . a .
InstallatIon
CTC6-10E, CTC6-10G
CTC10-10E, CTC10-10G
CTC7-20E, CTC7-20G
CTC10-20E, CTC10-20G
CTC20-10E, CTC20-10G
CTC20-20E, CTC20-20G
Consult
instructions
for installation
and use.
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
DANGER
DO NOT store or use gasoline or other
ammable vapors or liquids in the
vicinity of this or any other appliance.
Vedere la pagina 0
1 2 3 4 5 6 ... 66 67

Sommario

Pagina 1 - DANGER

MN-35947 • REV. 2 • 01/14CTP6-10E, CTP6-10GCTP10-10E, CTP10-10GCTP7-20E, CTP7-20GCTP10-20E, CTP10-20GCTP20-10E, CTP20-10GCTP20-20E, CTP20-20G 

Pagina 2 - InstallatIon

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 8.COMBITHERM® PRE-INSTALLATION CHECKLIST CONTINUEDDRAIN:Is there a

Pagina 3 - UNPACKING

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 9.*ELECTRICAL SERVICE CHARGE APPLIESELECTRICAL (NO CORD, NO PLUG,

Pagina 4 - AND PRECAUTIONS

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 10.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 5

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 11.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 6

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 12.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 7

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 13.*ELECTRICAL SERVICE CHARGE APPLIESELECTRICAL (NO CORD, NO PLUG,

Pagina 8 - ❑  ❑ 

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 14.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 9

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 15.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 10 - Left side 0" (0mm)

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 16.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 11 - CTP6-10E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 17.*ELECTRICAL SERVICE CHARGE APPLIESELECTRICAL (NO CORD, NO PLUG,

Pagina 12 - CTC6-10E

DANGERBEFORE STARTING THE APPLIANCE, MAKE CERTAIN YOU DO NOT DETECT THE ODOR OF GAS.IF THE ODOR OF GAS IS DETECTED:• DO NOT attempt to light any app

Pagina 13 - CTP6-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 18.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 14 - CTC6-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 19.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 15 - CTP10-10E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 20.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 16 - CTC10-10E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 21.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 17 - CTP10-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 22.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 18 - CTC10-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 23.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 19 - CTP7-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 24.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 20 - CTC7-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 25.*ELECTRICAL SERVICE CHARGE APPLIESELECTRICAL (NO CORD, NO PLUG,

Pagina 21 - CTP7-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 26.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 22 - CTC7-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 27.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 23 - CTP10-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 1.THE INFORMATION CONTAINED IN THIS MANUAL IS IMPORTANT FOR THE PR

Pagina 24 - CTC10-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 28.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 25 - CTP10-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 29.*ELECTRICAL SERVICE CHARGE APPLIESELECTRICAL (NO CORD, NO PLUG,

Pagina 26 - CTC10-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 30.ELECTRICAL (NO CORD, NO PLUG, DEDICATED CIRCUIT REQUIRED) DO

Pagina 27 - CTP20-10E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 31.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 28 - CTC20-10E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 32.GAS REQUIREMENTS (GAS TYPE MUST BE SPECIFIED ON ORDER)HOOK-UP:

Pagina 29 - CTP20-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 33.INSTALLATIONSITE INSTALLATIONNOTE: Note dimensions required f

Pagina 30 - CTC20-10G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 34.POSITIONING ON SITEPlace the oven on a stable, non-combustible l

Pagina 31 - CTP20-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 35.INSTALLATIONOPTIONS & ACCESSORIESCOMBICLEAN® COMBITABS™ — S

Pagina 32 - CTC20-20E

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 36.INSTALLATIONELECTRICAL FOR GAS MODELS 1. An electrical wiring di

Pagina 33 - CTP20-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 37.ELECTRICAL FOR ELECTRIC MODELSINSTALLATION DANGERENSURE POWER

Pagina 34 - CTC20-20G

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 2.CAUTIONUsed to indicate the presence of a hazard that can or will

Pagina 35 - INSTALLATION

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 38.ELECTRICAL CONNECTIONINSTALLATION DANGERELECTRICAL CONNECTIONS

Pagina 36

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 39.INSTALLATIONMOBILE EQUIPMENT RESTRAINT FOR GAS MODELSThe gas Co

Pagina 37

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 40.INSTALLATIONVENTILATION REQUIREMENTS FOR GAS MODELSAn adequate v

Pagina 38

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 41.INSTALLATIONGAS SUPPLY & INSTALLATIONThe Alto-Shaam gas Com

Pagina 39

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 42.INSTALLATIONGAS SUPPLY & INSTALLATION

Pagina 40

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 43.INSTALLATIONGAS SUPPLY & INSTALLATIONThe minimum size requi

Pagina 41 - WARNING

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 44.INSTALLATIONGAS SUPPLY & INSTALLATIONLEAK TESTING

Pagina 42

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 45.INSTALLATIONWATER SUPPLY & INSTALLATION WARNINGTO PREVENT W

Pagina 43

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 46.INSTALLATIONWATER SUPPLY & INSTALLATIONWATER REQUIREMENTSWAT

Pagina 44

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 47.INSTALLATIONWATER DRAINAGE - EACH OVENA union is required. Ins

Pagina 45

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 3.INSTALLATIONSITE INSTALLATIONINSTALLATION CODES & STANDARDST

Pagina 46

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 48.INSTALLATIONCOMBIHOOD PLUS™ VENTLESS HOOD OPTIONThe CombiHood PL

Pagina 47

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 49.INSTALLATION Cleaning frequency shou

Pagina 48

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 50.INSTALLATION GREASE COLLECTION HOOK-UP ( i f e Q U i p p e d

Pagina 49

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 51.INSTALLATION LIQUID CLEANER HOOK-UP (IF EQUIPPED WITH THIS OPTI

Pagina 50

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 52.OPERATION CT PROFORMANCE™ START-UP PROCEDURESWhen the oven is po

Pagina 51

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 53.Turn on and preheat the ovenAlto-Shaam recommends preheating th

Pagina 52

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 54.COMBITHERM® POST INSTALLATION CHECKLIST

Pagina 53

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 55.COMBITHERM® POST INSTALLATION CHECKLIST

Pagina 54 - OPERATION

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 56.TROUBLE SHOOTINGThis section is provided for the assistance of q

Pagina 55

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 57.TROUBLE SHOOTINGError CodeError Call Out in Display Description

Pagina 56

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 4.INSTALLATION DUTIES & RESPONSIBILITIES - NEW CONSTRUCTION

Pagina 57

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 58.TROUBLE SHOOTINGERROR CODESError CodeError Call Out in Display D

Pagina 58 - TROUBLE SHOOTING

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 59.TROUBLE SHOOTINGERROR CODESError CodeError Call Out in Display

Pagina 59

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 60.TROUBLE SHOOTINGERROR CODESError CodeError Call Out in Display D

Pagina 60

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 61.see motor control error chart on next pageTROUBLE SHOOTINGERROR

Pagina 61

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 62.INSTALLATIONType of Error Indication Release of ErrorUndervoltag

Pagina 62

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 63.Item Part Description1 5014934 Directional Panel, 6-10E5016376

Pagina 63

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 64.ORIGINAL EQUIPMENT LIMITED WARRANTY Alto-Shaam, Inc. warrants t

Pagina 64

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 65.W164 N9221 Water Street ••

Pagina 65 - SERVICE PARTS

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 5.INSTALLATION DUTIES & RESPONSIBILITIES - RETRO FIT/EXISTING

Pagina 66

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 6.COMBITHERM® PRE-INSTALLATION CHECKLISTLocation Name: Date:Locatio

Pagina 67

COMBITHERM CT PROFORMANCE AND CT CLASSIC SERIES • INSTALLATION MANUAL • MN-35947 • 7.COMBITHERM® PRE-INSTALLATION CHECKLIST CONTINUEDOVEN CLEARANCES: